Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA bracket to run stress or thermal on, free in your browser
Bambu Lab PAHT-CF, TDS V3.0, printed specimens X-Y, dry state; nozzle 290 °C, bed 100 °C, 100 mm/s, 100% infill; annealed and dried 80 °C for 12 h before testing.
FDM Polycarbonate
Ultimaker PC, 3D-printed specimens, XY (flat); Ultimaker S5 Pro, engineering intent profile, 0.15 mm layer height, AA 0.4 print core, 100% infill, Cura 4.9, printed one-at-a-time, conditioned >=24 h at room temperature. TDS (file v5.00), April 20, 2022.
1
Ultimaker PC Technical Data Sheet, v5.00UltiMakerarchived copyFDM Polycarbonate · Yield strength: typicalFDM Polycarbonate · Ultimate tensile strength: typical, peak stress (= stress at yield)FDM Polycarbonate · Flexural strength: typicalFDM Polycarbonate · Elongation at break: typicalFDM Polycarbonate · Young's modulus (stiffness): typicalFDM Polycarbonate · Density: rangeFDM Polycarbonate · Glass transition: typicalFDM Polycarbonate · Max service temperature: HDT 0.455 MPa (printed specimens)
Engineering Polymers Part and Mold Design: Thermoplastics, A Design GuideCovestroarchived copyFDM Polycarbonate · Poisson's ratio: base material: polycarbonate family typical (Covestro Part and Mold Design guide, Table 3-1)
4
Makrolon 2405 Technical Data SheetCovestroFDM Polycarbonate · Thermal conductivity: base material: Covestro Makrolon 2405 injection-molding PC, typical, through-plane, 23 °CFDM Polycarbonate · Thermal expansion: base material: Covestro Makrolon 2405 injection-molding PC, typical, 23-55 °C, parallel
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
FDM PAHT-CF and FDM Polycarbonate are 3D printed: their properties depend on build direction and print settings; these are typical values.
Questions
Mechanical
Is FDM PAHT-CF stronger than FDM Polycarbonate?
FDM PAHT-CF is stronger: its tensile strength is 92 MPa against yield strength 53.3 MPa for FDM Polycarbonate (1.73x).
Which is lighter, FDM PAHT-CF or FDM Polycarbonate?
FDM PAHT-CF is lighter: 1,060 kg/m³ against 1,190 kg/m³ for FDM Polycarbonate.
Which is stiffer, FDM PAHT-CF or FDM Polycarbonate?
FDM PAHT-CF is stiffer: Young's modulus 3.86 GPa against 2.39 GPa for FDM Polycarbonate, so the same part in FDM PAHT-CF deflects less under the same load.
Which is lighter for the same job, FDM PAHT-CF or FDM Polycarbonate?
For the same stiffness or strength: FDM PAHT-CF is lighter for a stiff rod or tie (tension), stiff beam (bending), stiff panel or plate, strong rod or tie, strong beam, strong panel or plate.
Part that must be
FDM PAHT-CF
FDM Polycarbonate
Stiff rod or tie (tension)
lighter
1.81x heavier
Stiff beam (bending)
lighter
43% heavier
Stiff panel or plate
lighter
32% heavier
Strong rod or tie
lighter
1.94x heavier
Strong beam
lighter
1.62x heavier
Strong panel or plate
lighter
47% heavier
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).