Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Try it on a partA bracket to run stress or thermal on, free in your browser
Sources3 documents: Bambu Lab, EOS GmbH, INEOS Styrolution
FDM ASA
Bambu Lab ASA, TDS V3.0, printed specimens X-Y; nozzle 260 °C, bed 80 °C, 200 mm/s, 100% infill; annealed and dried 80 °C for 12 h before testing.
SLS PA12 Nylon
EOS PA 2200 (PA12) Material Data Sheet, process parameter 'Balance' at 120 µm layer thickness, X orientation, dry (conditioned values not given). Live MDS status 04.10.2026, last changed 10.09.2026; PDF via ?topdf=... link on the same page.
PA 2200 Balance Material Data SheetEOS GmbHSLS PA12 Nylon · Ultimate tensile strength: typicalSLS PA12 Nylon · Elongation at break: typicalSLS PA12 Nylon · Young's modulus (stiffness): typicalSLS PA12 Nylon · Density: typicalSLS PA12 Nylon · Melting point: typicalSLS PA12 Nylon · Max service temperature: HDT 1.8 MPa, X orientation
3
Luran S 777K (ASA) Product Data SheetINEOS StyrolutionFDM ASA · Thermal conductivity: base material: INEOS Styrolution Luran S 777K injection-molding ASA, typicalFDM ASA · Thermal expansion: base material: INEOS Styrolution Luran S 777K injection-molding ASA, range
Each number points to the document that states it, with the exact basis. Values without a number are computed from the sourced ones. "Not sourced" means no citable source states it (or only a specification minimum); figures computed from it are left out too.
FDM ASA and SLS PA12 Nylon are 3D printed: their properties depend on build direction and print settings; these are typical values.
Questions
Mechanical
Is FDM ASA stronger than SLS PA12 Nylon?
SLS PA12 Nylon is stronger: its tensile strength is 48 MPa against 37 MPa for FDM ASA (30%).
Which is lighter, FDM ASA or SLS PA12 Nylon?
SLS PA12 Nylon is lighter: 930 kg/m³ against 1,050 kg/m³ for FDM ASA.
Which is stiffer, FDM ASA or SLS PA12 Nylon?
FDM ASA is stiffer: Young's modulus 2.45 GPa against 1.65 GPa for SLS PA12 Nylon, so the same part in FDM ASA deflects less under the same load.
Which is lighter for the same job, FDM ASA or SLS PA12 Nylon?
For the same stiffness or strength: FDM ASA is lighter for a stiff rod or tie (tension), stiff beam (bending), stiff panel or plate; SLS PA12 Nylon is lighter for a strong rod or tie, strong beam, strong panel or plate.
Part that must be
FDM ASA
SLS PA12 Nylon
Stiff rod or tie (tension)
lighter
32% heavier
Stiff beam (bending)
lighter
8% heavier
Stiff panel or plate
lighter
1% heavier
Strong rod or tie
46% heavier
lighter
Strong beam
34% heavier
lighter
Strong panel or plate
29% heavier
lighter
For the same stiffness or strength, mass scales with density over stiffness (or strength) raised to a power set by how the part is loaded: 1 for a rod in tension, 1/2 for a beam in bending, 1/3 for a panel (the standard material-selection indices).
Which is more ductile, FDM ASA or SLS PA12 Nylon?
SLS PA12 Nylon stretches further before it breaks: 18% elongation at break against 9.2% for FDM ASA.
Thermal
Which handles higher temperatures, FDM ASA or SLS PA12 Nylon?
FDM ASA does: 92 °C against 64 °C for SLS PA12 Nylon.