Thermal conductivity against densityHigher and further left: spreads more heat for its weightThermal expansion against thermal conductivityLower and further right: warps less when heated
Sources3 documents: Formlabs
Values for
3D printed (SLA resin). Formlabs Clear Resin V5 (FLGPCL05), TDS Rev. 01 March 20, 2024; printed on Form 4 at 100 µm, washed 5 min in >=99% IPA, post-cured 15 min at 60 °C in Form Cure. Orientation not stated.
1
Clear Resin V5 Technical Data Sheet (2024)Formlabsarchived copyUltimate tensile strength: typicalFlexural strength: typicalElongation at break: typicalYoung's modulus (stiffness): typicalMax service temperature: HDT 1.8 MPa
2
Clear Resin V5 Technical Data Sheet (web edition)FormlabsDensity: typical, post-cured (same for 5 min ambient and 15 min at 60 °C), ASTM D792
3
Thermal Properties of Selected Formlabs SLA ResinsFormlabsThermal conductivity: typical, post-cured, ASTM E1530Thermal expansion: mean -30 to 140 °C, post-cured (5 min ambient cure), TMA ASTM E831Specific heat: typical, 25 °C, post-cured (5 min ambient cure), DSC ASTM E1269
SLA Resin Standard is 3D printed: its properties depend on build direction and print settings; these are typical values.
SLA Resin Standard has a thermal conductivity of 0.54 W/m·K (0.312 BTU/hr·ft·°F). Basis: typical, post-cured, ASTM E1530. Source: Formlabs, Thermal Properties of Selected Formlabs SLA Resins.
Specific heat of SLA Resin Standard
The specific heat capacity of SLA Resin Standard is 1,800 J/kg·K (0.43 BTU/lb·°F). Basis: typical, 25 °C, post-cured (5 min ambient cure), DSC ASTM E1269. Source: Formlabs, Thermal Properties of Selected Formlabs SLA Resins.
Coefficient of thermal expansion of SLA Resin Standard
SLA Resin Standard expands 114 µm/m·K (63.4 µin/in·°F): a 100 mm part grows 571 µm over a 50 °C rise. Basis: mean -30 to 140 °C, post-cured (5 min ambient cure), TMA ASTM E831. Source: Formlabs, Thermal Properties of Selected Formlabs SLA Resins.
Thermal diffusivity of SLA Resin Standard
Computed from the conductivity, density and specific heat (k / ρc): 0.248 mm²/s, how fast a temperature change spreads through it.
Maximum service temperature of SLA Resin Standard
The maximum service temperature of SLA Resin Standard is 59 °C (138 °F). Basis: HDT 1.8 MPa. Source: Formlabs, Clear Resin V5 Technical Data Sheet (2024)archived copy.